ANALISA KOMPARASI DAYA DUKUNG PONDASI BORED PILE SECARA ANALISTIS TERHADAP HASIL LOADING TEST STUDI KASUS PROYEK PEMBANGUNAN REZ HOTEL

Savira Mirda Anggraeni, Hartopo Hartopo, Totok Apriyanto

Abstract


Foundation failure and other factors that can cause bearing capacity to be incompatible when in the field. This is one of the factors that encourage direct loading tests in the field. Main objective of this study is to s to calculate and compare the ultimate bearing capacity of drilled pile after implementation with ultimate bearing capacity at the time of planning. SPT results were calculated using the Aoki Velosso method, the Decourt method, and the Reese & Wright method. Based on the calculation of the carrying capacity that has been carried out, there are differences in results, both due to the use of the method and the location of the point being reviewed. Based on the SPT data obtained from the calculation results of each Aoki Velosso method for TP-1/BP.48 the value of Qu = 783,933 tons while for TP-3/BP.78 the value of Qu = 1301,239, the Decont method for TP-1/BP.48 values Qu = 2593.098 tons while for TP-3/BP.78 the value of Qu = 2091.817, the Reese & Wright method for TP-1/BP.48 the value of Qu = 401.030ton while for TP-3/BP.78 the value of Qu = 334.022 and the results The loading test of the two test piles is TP-1/BP.48 Qu = 256 tons and TP-3/BP.78 Qu = 257 tons. Based on the calculation results, it can be seen that the efficient method used is the Reese & Wright method because the results of the calculation method are the smallest results, this is necessary to maintain building safety.

Full Text:

PDF

References


Jusi, U., 2015. Analisa Kuat Dukung Pondasi Bored Pile berdasarkan Data Pengujian Lapangan (Cone dan NStandard Penetration Test), Jurnal Teknik Sipil Sekolah Tinggi Teknologi Pekanbaru.

Hulu, H. B., 2015. Analisa Daya Dukung Pondasi Bored Pile dengan Menggunakan Metode Analitis (Studi Kasus Proyek Pembangunan Manhattan Mall dan Condominium), Jurusan Teknik Sipil, Fakultas Teknik Universitas Sumatera Utara.

Widia, W., dkk.,. Evaluai Daya Dukung Pondasi Bored Pile Terhadap Uji Pembangunan Langsung Pada Proyek Pembangunan AEON MALL MIXED USE SENTUL CITY BOGOR, Jurusan Teknik Sipil, Fakultas Teknik Universitas Pakuan.

Pratama, Y. A., 2018. Analisa Perbandingan Kapasitas Daya Dukung Pondasi Bore Pile Dengan Menggunakan Metode Empiris dan Dinamik Pada Jalan Tol Pandaan – Malang, Jurusan Teknisk Sipil, Fakultas Teknik Universitas Jember.

Hardiyatmo, C. H., 2015. Fondasi II. Yogyakarta: Gadjah Mada Universitas Press.

ASTM D 1586-84. Standard Penetration Test and Split Barrel Sampling of Soils.


Article Metrics

Abstract view : 24 times
PDF - 10 times

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.